Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.343
Filtrar
1.
J Arthroplasty ; 39(4): 991-996, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38661490

RESUMO

BACKGROUND: We aimed to compare the clinical outcomes of different head sizes (28-, 32-, and 36- millimeter) in primary total hip arthroplasty (THA) at mean 6 years follow-up (range, 1 to 17.5 years). METHODS: This was a retrospective consecutive study of primary THA at our institution (2003 to 2019). Demographic and surgical data were collected. The primary outcome measures were all-cause revision, revision for dislocation, and all-cause revision excluding dislocation. Continuous descriptive statistics used means, median values, ranges, and 95% confidence intervals, where appropriate. Kaplan-Meier survival curves were used to estimate time to revision. Cox proportional hazard regression analyses were used to compare revision rates between the femoral head size groups. Adjustments were made for age at surgery, sex, primary diagnosis, American Society of Anesthesiologists score, articulation type, and fixation methods. There were 10,104 primary THAs included; median age was 69 years (range, 13 to 101) with 61.5% women. A posterior approach was performed in 71.6%. There were 3,295 hips with 28-mm heads (32.6%), 4,858 (48.1%) with 32-mm heads, and 1,951 (19.3%) with 36-mm heads. RESULTS: Overall rate of revision was 1.7% with the lowest rate recorded for the 36-mm group (2.7 versus 1.3 versus 1.1%). Cox regression analyses showed a decreased risk of all-cause revision for 32 and 36-mm head sizes as compared to 28-mm; this was statistically significant for the 32-mm group (P = .01). Risk of revision for dislocation was significantly reduced in both 32-mm (P = .03) and 36-mm (P = .03) head sizes. Analysis of all cause revision excluding dislocation showed no significant differences between head sizes. CONCLUSIONS: We found a significantly reduced risk of revision for all causes, but particularly revision for dislocation with larger head sizes. Concerns regarding increased risk of early revision for aseptic loosening, polyethylene wear, or taper corrosion with larger heads appear to be unfounded in this cohort of 10,104 patients with up to 17 years follow-up.


Assuntos
Artroplastia de Quadril , Cabeça do Fêmur , Prótese de Quadril , Falha de Prótese , Reoperação , Humanos , Artroplastia de Quadril/instrumentação , Feminino , Masculino , Reoperação/estatística & dados numéricos , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Adulto , Cabeça do Fêmur/cirurgia , Idoso de 80 Anos ou mais , Adolescente , Desenho de Prótese , Adulto Jovem , Seguimentos , Fatores de Risco
2.
BMC Musculoskelet Disord ; 25(1): 312, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649874

RESUMO

BACKGROUND: Hip offset, version, and length are interdependent femoral variables which determine stability and leg length. Balancing these competing variables remains a core challenge in hip arthroplasty. The potential benefits of modular femoral stems have been overshadowed by higher rates of failure. The objective of this study was to assess the survivorship of a unique dual-modular femoral stem at an average 15-year follow-up period. METHODS: The records of all patients with osteoarthritis who underwent primary total hip arthroplasty with this device between 2004-2009 were reviewed. There were no exclusions for BMI or other factors. We examined the data with Kaplan-Meier survival analysis. The primary endpoint for survival was mechanical failure of the modular neck-body junction. RESULTS: The survivorship of this device in 172 subjects was 100% with none experiencing mechanical failure of the modular junction at an average of 15 years. 60 patients died of causes unrelated to their THA and 9 patients were lost to follow-up. There were three early (≤ 12 months) dislocations (1.7%), and seven total dislocations (4.1%). 16 patients underwent reoperations during the follow-up period, none for any complication of the modular junction. Radiographic results showed well-fixed femoral stems in all cases. There were no leg length discrepancies of greater than 10 mm, and 85% were within 5 mm. CONCLUSION: There were no mechanical failures of the modular junction in any of the subjects over the average 15-year period, demonstrating that this dual-modular design is not associated with increased failure rates. We achieved a 1.7% early dislocation rate and a 4.1% total dislocation rate without any clinically significant leg length discrepancies.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Desenho de Prótese , Falha de Prótese , Humanos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Adulto , Seguimentos , Osteoartrite do Quadril/cirurgia , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Estimativa de Kaplan-Meier , Reoperação/estatística & dados numéricos , Fêmur/cirurgia , Fêmur/diagnóstico por imagem , Fatores de Tempo
3.
Int J Artif Organs ; 47(4): 290-298, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38584296

RESUMO

BACKGROUND: Dislocation is a major complication of total hip arthroplasty (THA). The modular femoral neck system provides practical advantages by allowing adjustment of neck version and length in the presence of intraoperative instability. Anatomical studies have identified morphological differences in the hip joint between men and women. Despite sex-based differences in hip morphology, it remains unclear whether such differences affect neck selectivity in THA using a modular neck system and whether this approach achieves anatomical reconstruction, thereby reducing complications such as dislocation. This study aimed to investigate gender differences in neck selectivity in THA with the modular neck system and assess the clinical impact of the modular neck system. METHODS: A total of 163 THAs using a modular neck system were included in this study. Data on the type of modular neck and intraoperative range of motion (ROM) were retrieved from patient records. Pre- and post-operative leg length differences (LLD) were examined as part of the radiographic assessment. Dislocation was investigated as a postoperative complication. RESULTS: Neck selectivity did not significantly differ between men and women. The comparison of pre- and post-operative LLD revealed a tendency for varus necks to improve LLD more than version-controlled necks. Furthermore, no significant correlation was found between intraoperative ROM and neck selectivity, or postoperative dislocation and neck selectivity. CONCLUSIONS: This study on THA with a modular neck system provided valuable insights into sex-based differences in neck selectivity and highlighted the potential benefits of the modular neck system in addressing LLD and preventing postoperative dislocation.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Desenho de Prótese , Amplitude de Movimento Articular , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Artroplastia de Quadril/instrumentação , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Fatores Sexuais , Colo do Fêmur/cirurgia , Idoso de 80 Anos ou mais , Articulação do Quadril/cirurgia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/fisiopatologia , Estudos Retrospectivos , Adulto , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/etiologia , Resultado do Tratamento
4.
Int J Artif Organs ; 47(4): 299-302, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38515386

RESUMO

This article describes three cases in which a dislocated hip prosthesis was reduced by a new reduction technique - that we previously described - using traction table. The dissociation of a prosthesis is a rare but serious complication of closed reduction manoeuvre. The new reduction manoeuvre using a traction table may be a good option to avoid dissociation of the prosthesis during closed reduction for treatment of dislocation after total hip arthroplasty.


Assuntos
Artroplastia de Quadril , Luxação do Quadril , Prótese de Quadril , Tração , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Idoso , Feminino , Masculino , Luxação do Quadril/cirurgia , Luxação do Quadril/etiologia , Luxação do Quadril/diagnóstico por imagem , Falha de Prótese , Pessoa de Meia-Idade , Resultado do Tratamento
5.
Int J Surg ; 110(4): 2141-2150, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38241325

RESUMO

OBJECTIVE: To compare the effect of a new complete robot-assisted total hip arthroplasty (RA-THA) with that of the manual total hip arthroplasty (MTHA) and to verify the accuracy and safety of the former. METHODS: Overall, 148 patients were enroled from 3 March 2021 to 28 December 2021 in this study and classified into RA-THA ( n =74 patients) and MTHA ( n =74 patients) groups. The sex, age, operative side, BMI, diagnosis, other basic information, operative time, acetabular prosthesis anteversion and inclination, femoral prosthesis anteversion and angulation, femoral prosthesis filling rate, leg length discrepancy (LLD), Harris hip score, and visual analogue scale (VAS) score of the two groups were compared. RESULTS: No significant differences were observed in the two groups regarding sex, age, operative side, BMI, diagnosis, Harris hip score, VAS score, acetabular inclination, acetabular prosthesis anteversion, femoral prosthesis anteversion, combined anteversion, and femoral prosthesis filling rate ( P >0.05). The operative time was significantly longer in the RA-THA group than in the MTHA group (106.71±25.22 min vs. 79.42±16.16 min; t=7.30, P <0.05). The femoral angulation (1.78°±0.64°) and LLD (2.87±1.55 mm) in the RA-THA group were significantly lesser than those in the MTHA group (2.22°±1.11° and 5.81±6.27 mm, respectively; t=-2.95 and t=-3.88, P <0.05). CONCLUSION: The complete RA-THA has some advantages over the traditional procedure in restoring the lower limb length and controlling the femoral prosthesis angulation. Thus, this study verifies the accuracy and safety of the robot-assisted system.


Assuntos
Artroplastia de Quadril , Procedimentos Cirúrgicos Robóticos , Humanos , Masculino , Feminino , Artroplastia de Quadril/métodos , Artroplastia de Quadril/instrumentação , Procedimentos Cirúrgicos Robóticos/métodos , Pessoa de Meia-Idade , Idoso , Duração da Cirurgia , Resultado do Tratamento , Prótese de Quadril
6.
J Arthroplasty ; 38(2): 389-396.e1, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35964855

RESUMO

BACKGROUND: Porous metal augments are used in complex hip arthroplasty; however, few studies have assessed their efficacy and safety. This systematic review analyzed the use of augments in revision hip arthroplasty and summarized the clinical research findings. METHODS: We used combinations of "revision," "replacement," "arthroplasty," "augment," "acetabular," and "hip" to search PubMed, Web of Science, EMBASE, Cochrane Library databases, and clinical trial registration platform "Clinicaltrials" for relevant literature. The functional score, restoration of hip center of rotation, revision of implants, and complications were analyzed. Patients were divided into 3 subgroups according to the mean follow-up period. Overall, 19 reports involving 647 patients (655 hips) were selected. The mean age at the time of surgery was 63 years (range, 24-106) and the mean follow-up duration was 66 months (range, 11-204). RESULTS: Harris Hip Score increased from approximately a mean of 40 points preoperatively to a mean of 84 points postoperatively. The vertical distance between hip center of rotation and teardrop was restored from a preoperative distance of 41.9 to 21.7 mm postoperatively. The overall acetabular revision rate was 4.7%, and the incidence of complications was 8.2%. There were significant differences in the reoperation, acetabular revision, and complication rates among the subgroups. CONCLUSION: Metal augments used in revision hip arthroplasty are a safe and effective treatment option to correct acetabular defects.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Metais , Humanos , Acetábulo/cirurgia , Artroplastia de Quadril/instrumentação , Seguimentos , Prótese de Quadril/efeitos adversos , Metais/efeitos adversos , Falha de Prótese , Reoperação , Resultado do Tratamento
7.
Orthopadie (Heidelb) ; 51(10): 815-821, 2022 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-36069911

RESUMO

INTRODUCTION: Osteonecrosis of the femoral head or avascular necrosis of the femoral head (HKN) is a complex disease that, without treatment, leads to infraction of the femoral head in most cases. In these cases, only replacement of the hip joint will help, although there is no clear recommendation of an arthroplasty type. In the last two decades, the treatment of primary and secondary coxarthrosis with short-shaft prostheses with different anchoring philosophies has increased. Since short-shaft fitting is a possible option especially in younger patients, the question arises about possible fittings of advanced HKN with these stem types, especially with metaphyseal anchorage. The aim of this study was to review the existing literature on the results of short stem prosthesis in HKN and to present the advantages and disadvantages of short stem prosthesis in osteonecrosis of the femoral head. MATERIAL AND METHODS: This review analyzes the existing studies on short stem arthroplasty for HKN. RESULTS: Only a few studies exist that have analyzed clinical and radiologic outcomes of short stem replacement in HKN. CONCLUSION: The existing short- and medium-term results show mostly good outcomes. However, it is difficult to draw a general conclusion due to differences in stem design and fixation. Short stems with primary diaphyseal fixation do not show an increased risk of failed osseointegration or loosening. Constructions with primary metaphyseal fixation should undergo MRI to rule out the possibility of necrosis extending beyond the femoral neck.


Assuntos
Artroplastia de Quadril , Necrose da Cabeça do Fêmur , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Cabeça do Fêmur/cirurgia , Necrose da Cabeça do Fêmur/diagnóstico por imagem , Prótese de Quadril/efeitos adversos , Humanos , Resultado do Tratamento
8.
J Orthop Surg Res ; 17(1): 293, 2022 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-35658905

RESUMO

BACKGROUND: Ceramic bearings are used in total hip arthroplasty due to their excellent wear behaviour and biocompatibility. The major concern related to their use is material brittleness, which significantly impacts on the risk of fracture of ceramic components. Fracture toughness improvement has contributed to the decrease in fracture rate, at least of the prosthetic head. However, the root cause behind these rare events is not fully understood. This study evaluated head fracture occurrence in a sizeable cohort of patients with fourth-generation ceramic-on-ceramic implants and described the circumstances reported by patients in the rare cases of head fracture. METHODS: The clinical survivorship of 29,495 hip prostheses, with fourth-generation ceramic bearings, was determined using data from a joint replacement registry. The average follow-up period was 5.2 years (range 0.1-15.6). Retrieval analysis was performed in one case for which the ceramic components were available. RESULTS: Clinical outcomes confirmed the extremely low fracture rate of fourth-generation ceramic heads: only two out of 29,495 heads fractured. The two fractures, both involving 36 mm heads, occurred without a concurrent or previous remarkable trauma. Considering the feature of the fractured head, a multi-stage crack growth mechanism has been hypothesized to occur following damage at the head-neck taper interface. CONCLUSIONS: Surgeons must continue to pay attention to the assembly of the femoral head: achieving a proper head seating on a clean taper is a prerequisite to decrease the risk of occurrence of any damage process within head-neck junction, which may cause high stress concentration at the contact surface, promoting crack nucleation and propagation even in toughened ceramics.


Assuntos
Artroplastia de Quadril , Fraturas Ósseas , Prótese de Quadril , Artroplastia de Quadril/instrumentação , Cerâmica , Cabeça do Fêmur , Prótese de Quadril/efeitos adversos , Humanos , Desenho de Prótese , Falha de Prótese
9.
Acta Biomed ; 92(S3): e2021549, 2022 03 10.
Artigo em Inglês | MEDLINE | ID: mdl-35604256

RESUMO

BACKGROUND AND AIM: Loss of bone stock is the main problem in revision hip arthroplasty. Porous tantalum cups and augment constructs are possible solutions. The aim of this study was to describe results at an average follow-up of 10 years using these cups. METHODS: 25 patients underwent to revision hip arthroplasty with porous tantalum cups. Acetabular bone defects were classified according to Paprosky's in type II and III. All patients were reviewed clinically and radiographically at an average follow-up of 10 years (range 8.5 to 13 years). Changes in inclination angle of the cup and position of the hip centre of rotation (COR - measured and calculated using Pierchon's method), and possible periacetabular radiolucency lines were assessed. RESULTS: A statistically significant improvement in Harris Hip Score and hip range of motion was observed. The hip COR had been lowered by 19.33 mm after revision and no changes in COR position had been measured at follow-up. Kaplan-Meier survivorship was 100% at an average follow-up of 10 years, considering acetabular revision for any reasons as primary endpoint. 88% of patients was satisfied. Complications were 3 dislocations, 4 asymptomatic heterotopic ossifications and 1 partial reabsorption of greater trochanter. CONCLUSIONS: Porous tantalum cups and augments can be considered a valid solution in acetabular revisions for addressing massive bone defects and restoring the hip COR.


Assuntos
Acetábulo , Artroplastia de Quadril , Articulação do Quadril , Prótese de Quadril , Acetábulo/cirurgia , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Materiais Biocompatíveis , Reabsorção Óssea/cirurgia , Seguimentos , Articulação do Quadril/cirurgia , Humanos , Porosidade , Desenho de Prótese , Falha de Prótese , Amplitude de Movimento Articular , Reoperação , Estudos Retrospectivos , Rotação , Tantálio
10.
Bone Joint J ; 104-B(2): 200-205, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35094568

RESUMO

AIMS: The aim of this study was to evaluate the performance of first-generation annealed highly cross-linked polyethylene (HXLPE) in cementless total hip arthroplasty (THA). METHODS: We retrospectively evaluated 29 patients (35 hips) who underwent THA between December 2000 and February 2002. The survival rate was estimated using the Kaplan-Meier method. Hip joint function was evaluated using the Japanese Orthopaedic Association (JOA) score. Two-dimensional polyethylene wear was estimated using Martell's Hip Analysis Suite. We calculated the wear rates between years 1 and 5, 5 and 10, 10 and 15, and 15 and final follow-up. RESULTS: The mean follow-up period was 19.1 years (SD 0.6; 17.3 to 20.1). The 19-year overall survival rate with the end point of all-cause revision was 97.0% (95% confidence interval (CI) 91 to 100). The mean JOA score improved from 43.2 (SD 10.6; 30 to 76) before surgery to 90.2 (SD 6.4; 76 to 98) at the final follow-up (p < 0.001). There was no osteolysis or loosening of the acetabular or femoral components. The overall steady-state wear rate was 0.013 mm/year (SD 0.012). There was no hip with a steady-state wear rate of > 0.1 mm/year. There was no significant difference in wear rates for each period. We found no significant correlation between the wear rate and age, body weight, BMI, or cup inclination. CONCLUSION: First-generation annealed HXLPE shows excellent wear resistance and no acceleration of wear for approximately 20 years, with low all-cause revision rates. Cite this article: Bone Joint J 2022;104-B(2):200-205.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Polietileno , Desenho de Prótese , Falha de Prótese/tendências , Adulto , Idoso , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Reoperação/estatística & dados numéricos , Estudos Retrospectivos
11.
Bone Joint J ; 104-B(2): 212-220, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35094572

RESUMO

AIMS: Femoral cement-in-cement revision is a well described technique to reduce morbidity and complications in hip revision surgery. Traditional techniques for septic revision of hip arthroplasty necessitate removal of all bone cement from the femur. In our two centres, we have been using a cement-in-cement technique, leaving the distal femoral bone cement in selected patients for septic hip revision surgery, both for single and the first of two-stage revision procedures. A prerequisite for adoption of this technique is that the surgeon considers the cement mantle to be intimately fixed to bone without an intervening membrane between cement and host bone. We aim to report our experience for this technique. METHODS: We have analyzed patients undergoing this cement-in-cement technique for femoral revision in infection, and present a consecutive series of 89 patients. Follow-up was undertaken at a mean of 56.5 months (24.0 to 134.7) for the surviving cases. RESULTS: Seven patients (7.9%) required further revision for infection. Ten patients died of causes unrelated to their infection before their two-year review (mean 5.9 months; 0.9 to 18.6). One patient was lost to follow-up at five months after surgery, and two patients died of causes unrelated to their hip shortly after their two-year review was due without attending. Of the remaining patients, 69 remained infection-free at final review. Radiological review confirms the mechanical success of the procedure as previously described in aseptic revision, and postoperative Oxford Hip Scores suggest satisfactory functional outcomes. CONCLUSION: In conclusion, we found that retaining a well-fixed femoral cement mantle in the presence of infection and undertaking a cement-in-cement revision was successful in 82 of the patients (92.1%) in our series of 89, both in terms of eradication of infection and component fixation. These results are comparable to other more invasive techniques and offer significant potential benefits to the patient. Cite this article: Bone Joint J 2022;104-B(2):212-220.


Assuntos
Artroplastia de Quadril/métodos , Infecções Bacterianas/cirurgia , Cimentos Ósseos , Candidíase/cirurgia , Prótese de Quadril , Infecções Relacionadas à Prótese/cirurgia , Reoperação/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/instrumentação , Infecções Bacterianas/etiologia , Candidíase/etiologia , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Reoperação/instrumentação , Resultado do Tratamento
12.
Bone Joint J ; 104-B(2): 206-211, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35094580

RESUMO

AIMS: Total hip arthroplasty (THA) is a very successful and cost-effective operation, yet debate continues about the optimum fixation philosophy in different age groups. The concept of the 'cementless paradox' and the UK 'Getting it Right First Time' initiative encourage increased use of cemented fixation due to purported lower revision rates, especially in elderly patients, and decreased cost. METHODS: In a high-volume, tertiary referral centre, we identified 10,112 THAs from a prospectively collected database, including 1,699 cemented THAs, 5,782 hybrid THAs, and 2,631 cementless THAs. The endpoint was revision for any reason. Secondary analysis included examination of implant survivorship in patients aged over 70 years, over 75 years, and over 80 years at primary THA. RESULTS: Cemented fixation had the lowest implant survival in all age groups, with a total ten-year survivorship of 97.0% (95% confidence interval (CI) 95.8 to 97.8) in the cemented group, 97.6% (95% CI 96.9 to 98.1) in the hybrid group, and 97.9% (95% CI 96.9 to 98.6) in the cementless group. This was not statistically significant (p = 0.092). There was no age group where cemented fixation outperformed hybrid or cementless fixation. CONCLUSION: While all fixation techniques performed well at long-term follow-up, cemented fixation was associated with the lowest implant survival in all age groups, including in more elderly patients. We recommend that surgeons should carefully monitor their own outcomes and use fixation techniques that they are familiar with, and deliver the best outcomes in their own hands. Cite this article: Bone Joint J 2022;104-B(2):206-211.


Assuntos
Artroplastia de Quadril/métodos , Cimentos Ósseos , Prótese de Quadril , Falha de Prótese/etiologia , Reoperação/estatística & dados numéricos , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/instrumentação , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Estudos Retrospectivos
13.
Bone Joint J ; 104-B(2): 193-199, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35094582

RESUMO

AIMS: This study aimed to use intraoperative free electromyography to examine how the placement of a retractor at different positions along the anterior acetabular wall may affect the femoral nerve during total hip arthroplasty (THA) when undertaken using the direct anterior approach (THA-DAA). METHODS: Intraoperative free electromyography was performed during primary THA-DAA in 82 patients (94 hips). The highest position of the anterior acetabular wall was defined as the "12 o'clock" position (middle position) when the patient was in supine position. After exposure of the acetabulum, a retractor was sequentially placed at the ten, 11, 12, one, and two o'clock positions (right hip; from superior to inferior positions). Action potentials in the femoral nerve were monitored with each placement, and the incidence of positive reactions (defined as explosive, frequent, or continuous action potentials, indicating that the nerve was being compressed) were recorded as the primary outcome. Secondary outcomes included the incidence of positive reactions caused by removing the femoral head, and by placing a retractor during femoral exposure; and the incidence of femoral nerve palsy, as detected using manual testing of the strength of the quadriceps muscle. RESULTS: Positive reactions were significantly less frequent when the retractor was placed at the ten (15/94; 16.0%), 11 (12/94; 12.8%), or 12 o'clock positions (19/94; 20.2%), than at the one (37/94; 39.4%) or two o'clock positions (39/94; 41.5%) (p < 0.050). Positive reactions also occurred when the femoral head was removed (28/94; 29.8%), and when a retractor was placed around the proximal femur (34/94; 36.2%) or medial femur (27/94; 28.7%) during femoral exposure. After surgery, no patient had reduced strength in the quadriceps muscle. CONCLUSION: Placing the anterior acetabular retractor at the one or two o'clock positions (right hip; inferior positions) during THA-DAA can increase the rate of electromyographic signal changes in the femoral nerve. Thus, placing a retractor in these positions may increased the risk of the development of a femoral nerve palsy. Cite this article: Bone Joint J 2022;104-B(2):193-199.


Assuntos
Artroplastia de Quadril/métodos , Eletromiografia/métodos , Nervo Femoral/fisiopatologia , Complicações Intraoperatórias/prevenção & controle , Monitorização Neurofisiológica Intraoperatória/métodos , Traumatismos dos Nervos Periféricos/prevenção & controle , Acetábulo/cirurgia , Adulto , Idoso , Artroplastia de Quadril/instrumentação , Feminino , Nervo Femoral/lesões , Humanos , Complicações Intraoperatórias/etiologia , Masculino , Pessoa de Meia-Idade , Traumatismos dos Nervos Periféricos/etiologia , Estudos Prospectivos , Resultado do Tratamento
15.
Acta Orthop ; 93: 59-67, 2022 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-34678118

RESUMO

Background and purpose - The anatomical uncemented stem, SP-CL (Static Physiologicus - CementLess), designed to facilitate insertion and to avoid stress concentration at solitary contact points, has been on the market since 2014 but is not well documented. We studied its clinical performance, migration, and associated bone remodeling in a randomized controlled trial, with the Corail stem as control. Patients and methods - 79 patients (80 hips) were primarily recruited and 71 patients (72 hips, 36 SP-CL, 36 Corail) attended the last follow-up at 2 years. The Oxford Hip Score (OHS) was the primary outcome. In addition, we assessed stem migration, changes in bone mineral density, and development of radiolucencies by RSA, DXA, and conventional radiography. Results - At 2 years Oxford Hip Score was similar between the SP-CL and Corail stem. At 2 years the SP-CL stems showed a median distal migration of 0.23 mm (-0.1 to 5.2) and the Corail stems of 0.11 mm (-0.4 to 4.4). The SP-CL stems showed slightly more loss of bone mineral density in Gruen region 7 (p = 0.003). Interpretation - We found no difference in clinical results between the SP-CL and the well-documented Corail stem. The same stem stability was reached between 1 and 2 years postoperatively for both stems. As a next step we think that the SP-CL stem should be studied in a multi-center setting, before being accepted for general use.


Assuntos
Artroplastia de Quadril/instrumentação , Migração de Corpo Estranho , Prótese de Quadril , Desenho de Prótese , Absorciometria de Fóton , Adulto , Idoso , Densidade Óssea , Remodelação Óssea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Análise Radioestereométrica
16.
Acta Orthop ; 93: 37-42, 2022 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-34633905

RESUMO

Background and purpose - Almost all prosthetic implant brands include several variations. Most studies on implant performance investigate an implant system without sub-analysis of implant attributes. We studied the influence of design variations during the last 2 decades on implant survival of the most frequently used cemented femoral stem, the Lubinus SPII, reported to the Swedish Arthroplasty Register (SHAR). Patients and methods - Between 2000 and 2018, 100,032 cemented Lubinus SP II stems had been reported to SHAR. Patients with primary osteoarthritis operated on with stem length 150 mm together with a cemented cup from the same manufacturer (n = 76,530) were included in this analysis. Primary study outcome was non-infectious stem revision. Cox regression with adjustment for age, sex, surgical approach, and year of surgery was used. Hazard rates (HR) are presented with 95% confidence intervals (CI). Results - Average follow-up was 7.6 years (SD 4.2). At 18 years the overall stem survival was 99.1 (CI 98.9-99.3). Increased revision rate was observed for stems with extra offset, when a long or an extra-long head length had been used. Smaller stem sizes, in particular the smallest stem size (01), substantially increased the rate of mechanical failure as reflected by an almost 10 times increased rate of revision compared with the standard size (2). Interpretation - In this study with larger sample size and longer follow-up than previously presented from the same register, we observed more pronounced effects of previously documented design variations. Based on our results, surgeons using the Lubinus SPII stems are advised to consider an alternative solution if a Lubinus stem size 01, Lubinus extra offset, or an extra-long head seems to be the most suitable choice at the preoperative planning.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Desenho de Prótese , Falha de Prótese , Idoso , Cimentos Ósseos , Feminino , Humanos , Masculino , Sistema de Registros , Suécia
17.
Clin Orthop Relat Res ; 480(3): 485-491, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34596603

RESUMO

BACKGROUND: The introduction of crosslinked ultra-high molecular weight polyethylene (XLPE) acetabular liners has been very successful, with decreased wear and reduction in the rates of revision hip arthroplasties. XLPE is the preferred articulation for most surgeons; however, there are concerns about the long-term performance of XLPE liners created with different manufacturing processes, which may lead to time-dependent failure, including accelerated wear, after several years. QUESTIONS/PURPOSES: (1) What is the amount and rate of wear during the first 10 years using radiostereometric analysis (RSA) measurements of patients who had THAs that included a second-generation XLPE bearing? (2) Does the rate of wear change after 5 years in situ? METHODS: This is a brief follow-up of a previous RSA study. In that study, we prospectively enrolled 21 patients with osteoarthritis who underwent primary cementless THA with an XLPE acetabular liner (three cycles of 3Mrad annealed) and 32-mm articulation. That group represented 44% of the 48 THAs performed by the surgeon at the hospital where RSA was available; 16 had cemented hips, leaving 32 who were invited to participate in this study. Of those, 11 lived rurally and declined to participate, leaving 21 patients who were included in the initial study. Since then, three patients died, one developed dementia and could not participate, and one had revision THA for reasons other than wear, leaving 16 patients available for analysis at 10 years. Tantalum markers were inserted during surgery, and all patients had RSA radiographs taken at 1 week, 6 months, and 1, 2, 5, and 10 years postoperatively. Femoral head penetration into the acetabular component was measured with RSA, including bedding-in during the first year and annual wear thereafter. RESULTS: The median medial, proximal, anterior, two-dimensional (2D), and three-dimensional (3D) wear rates between 1 and 10 years were -0.001, 0.004, -0.012, 0.000, and 0.002 mm/year, respectively. No patient in this cohort had a proximal or 2D wear rate greater than 0.025 mm/year. The median proximal wear rate between 5 and 10 years (0.002 mm/year) was not greater than wear at 1 to 5 years (0.004 mm/year). CONCLUSION: Femoral head penetration in this second-generation XLPE liner remained very low at 10 years and accelerated wear after 5 years in situ did not occur. Concerns about late-onset wear from oxidation of irradiated-annealed XLPE were not observed. The low level of wear remains encouraging for the future clinical performance of this material. LEVEL OF EVIDENCE: Level II, therapeutic study.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Polietilenos , Desenho de Prótese , Falha de Prótese , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade , Análise Radioestereométrica , Fatores de Tempo
18.
Bone Joint J ; 103-B(12): 1783-1790, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34847713

RESUMO

AIMS: Total hip arthroplasty (THA) with dual-mobility components (DM-THA) has been shown to decrease the risk of dislocation in the setting of a displaced neck of femur fracture compared to conventional single-bearing THA (SB-THA). This study assesses if the clinical benefit of a reduced dislocation rate can justify the incremental cost increase of DM-THA compared to SB-THA. METHODS: Costs and benefits were established for patients aged 75 to 79 years over a five-year time period in the base case from the Canadian Health Payer's perspective. One-way and probabilistic sensitivity analysis assessed the robustness of the base case model conclusions. RESULTS: DM-THA was found to be cost-effective, with an estimated incremental cost-effectiveness ratio (ICER) of CAD $46,556 (£27,074) per quality-adjusted life year (QALY). Sensitivity analysis revealed DM-THA was not cost-effective across all age groups in the first two years. DM-THA becomes cost-effective for those aged under 80 years at time periods from five to 15 years, but was not cost-effective for those aged 80 years and over at any timepoint. To be cost-effective at ten years in the base case, DM-THA must reduce the risk of dislocation compared to SB-THA by at least 62%. Probabilistic sensitivity analysis showed DM-THA was 58% likely to be cost-effective in the base case. CONCLUSION: Treating patients with a displaced femoral neck fracture using DM-THA components may be cost-effective compared to SB-THA in patients aged under 80 years. However, future research will help determine if the modelled rates of adverse events hold true. Surgeons should continue to use clinical judgement and consider individual patients' physiological age and risk factors for dislocation. Cite this article: Bone Joint J 2021;103-B(12):1783-1790.


Assuntos
Artroplastia de Quadril/instrumentação , Análise Custo-Benefício , Fraturas do Colo Femoral/cirurgia , Custos de Cuidados de Saúde/estatística & dados numéricos , Luxação do Quadril/prevenção & controle , Prótese de Quadril/economia , Complicações Pós-Operatórias/prevenção & controle , Idoso , Artroplastia de Quadril/economia , Canadá , Feminino , Fraturas do Colo Femoral/economia , Luxação do Quadril/economia , Luxação do Quadril/etiologia , Humanos , Masculino , Cadeias de Markov , Modelos Econômicos , Complicações Pós-Operatórias/economia , Desenho de Prótese/economia , Qualidade de Vida , Anos de Vida Ajustados por Qualidade de Vida , Resultado do Tratamento
19.
Bone Joint J ; 103-B(12): 1774-1782, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34847718

RESUMO

AIMS: The aim of this study was to determine if uncemented acetabular polyethylene (PE) liner geometry, and lip size, influenced the risk of revision for instability or loosening. METHODS: A total of 202,511 primary total hip arthroplasties (THAs) with uncemented acetabular components were identified from the National Joint Registry (NJR) dataset between 2003 and 2017. The effect of liner geometry on the risk of revision for instability or loosening was investigated using competing risk regression analyses adjusting for age, sex, American Society of Anesthesiologists grade, indication, side, institution type, surgeon grade, surgical approach, head size, and polyethylene crosslinking. Stratified analyses by surgical approach were performed, including pairwise comparisons of liner geometries. RESULTS: The distribution of liner geometries were neutral (39.4%; 79,822), 10° (34.5%; 69,894), 15° (21.6%; 43,722), offset reorientating (2.8%; 5705), offset neutral (0.9%; 1,767), and 20° (0.8%; 1,601). There were 690 (0.34%) revisions for instability. Compared to neutral liners, the adjusted subhazard ratios of revision for instability were: 10°, 0.64 (p < 0.001); 15°, 0.48 (p < 0.001); and offset reorientating, 1.6 (p = 0.010). No association was found with other geometries. 10° and 15° liners had a time-dependent lower risk of revision for instability within the first 1.2 years. In posterior approaches, 10° and 15° liners had a lower risk of revision for instability, with no significant difference between them. The protective effect of lipped over neutral liners was not observed in laterally approached THAs. There were 604 (0.3%) revisions for loosening, but no association between liner geometry and revision for loosening was found. CONCLUSION: This registry-based study confirms a lower risk of revision for instability in posterior approach THAs with 10° or 15° lipped liners compared to neutral liners, but no significant difference between these lip sizes. A higher revision risk is seen with offset reorientating liners. The benefit of lipped geometries against revision for instability was not seen in laterally approached THAs. Liner geometry does not seem to influence the risk of revision for loosening. Cite this article: Bone Joint J 2021;103-B(12):1774-1782.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Desenho de Prótese , Falha de Prótese/etiologia , Reoperação/estatística & dados numéricos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Polietileno , Modelos de Riscos Proporcionais , Sistema de Registros , Risco , Adulto Jovem
20.
Sci Rep ; 11(1): 21763, 2021 11 05.
Artigo em Inglês | MEDLINE | ID: mdl-34741121

RESUMO

The aim of the study was to analyse the results of uncemented total hip replacement, using the Metha (metaphyseal) stem. A total of 158 patients (70 females and 88 males) were qualified to the study and submitted to total hip arthroplasty (183 procedures altogether), using the Metha stem. The mean age of the patients on the day of surgery was 51.7 years (the range from 17 to 69 years). The mean follow up period was 9.2 years (the range from 5 to 13.5 years). Preoperative assessments gave poor scores, according to the Merle d'Aubigne and Postel classification, modified by Charnley. The average improvement after surgery, according to the used scale, was 6.9 points. A very good outcome was recorded in 154 cases (84.2%), a good outcome was achieved in 20 cases (10.9%) and a poor outcome was confirmed in 9 cases, while no satisfactory case was observed. Poor outcomes were associated with implant loosening. Extraskeletal ossification was noted in 10 cases (5.5%). According to the Kaplan-Meier estimator, the 10-year survival was 93.2% and 97.3% for the whole implant and the stem alone, respectively. 1. Our follow-up period of more than 9 years on the average, indicates that Metha stems produce excellent clinical and functional results in operated young patients with advanced degenerative changes of the hip joint. 2. Assuming a proper qualification for the procedure, the absence of complications and a correct surgical technique, which is slightly more difficult, when compared to standard stem implantation, the risk of aseptic loosening is fairly negligible.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril/estatística & dados numéricos , Adolescente , Adulto , Idoso , Artroplastia de Quadril/estatística & dados numéricos , Artroplastia de Quadril/tendências , Humanos , Pessoa de Meia-Idade , Reoperação , Estudos Retrospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...